Blood pressure (section: physical state) was measured in all Lifelines participants aged 8 years and older during:
Blood pressure was measured with the participant seated. The size of the cuff was chosen according to the arm circumference of the participant. For systolic and diastolic blood pressure, the average of the final three readings was recorded.
At 1A and 2A, blood pressure was measured automatically using the DinaMap PRO100 or DinaMap PRO100V2 critikon-dinamap-pro-op-manual.pdf.
At 3A, blood pressure was measured automatically using the ABPM 7100.
Blood pressure was not taken in case of:
For assessment 1A, the average systolic blood pressure (SBP) and diastolic blood pressure (DBP) were calculated according to the following protocol. The calculation method per participant can be found in variable 'bpavg_calculation_all_m_v1'
If | Then |
---|---|
the difference between the two last successive SBP/DBP measurements is ≤ 15 mmHg | calculate the mean SBP/DBP by taking the average of the two last successive blood pressures |
the difference between the two last successive SBP/DBP measurements is > 15 mmHg | the average SBP/DBP is calculated by taking the average of the last and the previous measurements. For example if measurement 9 and 10 differs more than 15 mgHg, the average is taken from measurement 8 and 10 |
there are no two successive SBP/DBP measurements with a difference ≤ 15 mmHg, but there are at least two measurements with a difference ≤ 15 mmHg | mean SBP/DBP is calculated using all available measurements |
there are only two SBP/DBP measurements, but the difference is > 15 mmHg | the last measurement is regarded as the mean SBP/DBP |
there is only one SBP/DBP measurement | the measurement is regarded as the mean SBP/DBP |
none of the above | the mean SBP/DBP is reviewed and calculated manually by the medical professional (visual inspection of data) |
For assessment 2A, the average systolic and diastolic blood pressures were calculated using the second and third successful measurement. If the second and/or third measurement was not successful, the last successful measurement (out of a maximum of six) was used as the average value (note that occurred in very few cases). The calculation method per participant can be found in variable 'bpavg_calculation_all_m_v2'
ATTENTION: For assessment 3A, blood pressure data is currently on hold due to an error in the data processing. The problem is being fixed and quality controlled data will become available again soon.
The following variables were measured:
Label (ENG) | Label (NL) | Code | Variable | Assessment | Age |
---|---|---|---|---|---|
Left or right arm? | Linker of rechterarm? | bp_arm_all_m_1 | arm | 3A | 8+ |
type of cuff used | type bloeddrukband | bp_bandsize_all_m_1 | cuff | 1A 2A 3A | 8+ |
type of input results | manier van invoer bloeddrukwaarden | bp_entrytype_all_m_1 | bpinput | 1A 2A | 8+ |
mean average pressure (mmhg) | gemiddelde arteriële druk (mmhg) | bpavg_arterial_all_m_1 | map | 1A 2A | 8+ |
calculate method | bereken methode | bpavg_calculation_all_m_v1 | avgtype | 1A | 8+ |
calculate method | bereken methode | bpavg_calculation_all_m_v2 | avgtype_2 | 2A | 8+ |
diastolic blood pressure (mmhg) | diastolische druk (mmhg) | bpavg_diastolic_all_m_1 | dbp | 1A 2A | 8+ |
pulse rate in beats per minute | polsfrequentie in slagen per minuut | bpavg_pulse_all_m_1 | hbf | 1A 2A | 8+ |
systolic blood pressure (mmhg) | systolische druk (mmhg) | bpavg_systolic_all_m_1 | sbp | 1A 2A | 8+ |
mean average pressure in mm hg, individual measurement (1-3) | gemiddelde arteriële druk (mmhg), individuele meting (1-3) | bpraw_arterial_m_1_01-03 | 1-3_map | 1A 2A 3A | 8+ |
mean average pressure in mm hg, individual measurement (4-6) | gemiddelde arteriële druk (mmhg), individuele meting (4-6) | bpraw_arterial_m_1_04-06 | 4-6_map | 1A 2A | 8+ |
mean average pressure in mm hg, individual measurement (7-10) | gemiddelde arteriële druk (mmhg), individuele meting (7-10) | bpraw_arterial_m_1_07-10 | 7-10_map | 1A | 8+ |
diastolic blood pressure in mm hg, individual measurement (1-3) | diastolische druk (mmhg), individuele meting (1-3) | bpraw_diastolic_m_1_01-03 | 1-3_dbp | 1A 2A 3A | 8+ |
diastolic blood pressure in mm hg, individual measurement (4-6) | diastolische druk (mmhg), individuele meting (4-6) | bpraw_diastolic_m_1_04-06 | 4-6_dbp | 1A 2A | 8+ |
diastolic blood pressure in mm hg, individual measurement (7-10) | diastolische druk (mmhg), individuele meting (7-10) | bpraw_diastolic_m_1_07-10 | 7-10_dbp | 1A | 8+ |
pulse rate in beats per minute, individual measurement (1-3) | polsfrequentie in slagen per minuut, individuele meting (1-3) | bpraw_pulse_m_1_01-03 | 1-3_hbf | 1A 2A 3A | 8+ |
pulse rate in beats per minute, individual measurement (4-6) | polsfrequentie in slagen per minuut, individuele meting (4-6) | bpraw_pulse_m_1_04-06 | 4-6_hbf | 1A 2A | 8+ |
pulse rate in beats per minute, individual measurement (7-10) | polsfrequentie in slagen per minuut, individuele meting (7-10) | bpraw_pulse_m_1_07-10 | 7-10_hbf | 1A | 8+ |
systolic blood pressure in mm hg, individual measurement (1-3) | systolische druk (mmhg), individuele meting (1-3) | bpraw_systolic_m_1_01-03 | 1-3_sbp | 1A 2A 3A | 8+ |
systolic blood pressure in mm hg, individual measurement (4-6) | systolische druk (mmhg), individuele meting (4-6) | bpraw_systolic_m_1_04-06 | 4-6_sbp | 1A 2A | 8+ |
systolic blood pressure in mm hg, individual measurement (7-10) | systolische druk (mmhg), individuele meting (7-10) | bpraw_systolic_m_1_07-10 | 7-10_sbp | 1A | 8+ |