User Tools

Site Tools


ecg

This is an old revision of the document!


12-lead electrocardiogram

Resting ECGs (section: physical state) were taken in Lifelines participants aged 13 years and older during:

Background

The 12-lead resting ECG measures electrical activity of the heart during rest, summarized in 12 leads.
The ECG provides many (>400) different variables at once, both quantitative and qualitative traits. These include duration, voltage and configuration characteristics. For example, information is provided of the cardiac rhythm, heart rate, the function of the sinoatrial and the atrioventricular node, atrial size, left ventricular mass, and repolarisation time (e.g. QT time).

Device

Welch Allyn CardioPerfekt Workstation ecg_manual.pdf
Welch Allyn CardioPerfect Workstation Software ecg_software_manual.pdf
DT100 vacuum units (suction electrode system).

Protocol

Electrodes were placed with conduction spray on ten clean spots at the abdomen and left side of the chest of lying participants (see illustration). In case of dextrocardia, the electrodes were mirrored.

All ECGs were checked by the research nurse and the Welch Allyn algorithm using CardioPerfekt software (see flow chart). ECG deviations (atrium fibrillation, atrium flutter, bradycardia, tachycardia, infoaction, acute ischemia, ST elevation, Wolff Parkinson White Syndrome, bigemenia, Left Bundle Branch Block, >1 premature ventricular contraction, second or third grade AV-block, pacemaker) were reported to a cardiologist.

Variables

The ECG resulted in the following variables:

Label English Code Variable Assessment Age
ecg performed ecg_performed_all_m_1 ecgond_1 1A 13+
ecg performed ecg_performed_all_m_2 ecgond_2 2A 13+
if not, reason: / ecg performed ecg_performed_all_m_2_a ecg_reden 2A 13+
ecg device code ecg_devicecode_all_m_1 ecgdevice 2A 13+
is ecg to be manually reviewed by a doctor? ecg_toreview_all_e_1 review 1A 2A 13+
system evaluation ecg ecg_toreview_all_e_3 systeem 3A 4A 13+
is the ecg manually reviewed by a doctor? ecg_reviewed_all_e_1 reviewed 1A 2A 13+
automatic interpretation by welch allyn ecg_welchallyn_all_m_1 means 1A 2A 13+
type of lead set used for analysis of paedriatic ecg ecg_paediatric_all_m_1 afleidingenset 3A
ecg technician - category of ECG review ecg_category_all_e_1 ecg_functieanalist_ecg_category 3A 4A 13+
ecg technician - technical review ecg_conclusion_all_e_3 ecg_functieanalist_ecg_conclusion 3A 4A 13+
ecg technician - advise to GP based on ecg review ecg_gpadvise_all_e_1 ecg_functieanalist_ecg_feedback_gp 3A 4A 13+
heart rate ecg_heartrate_all_m_1 hr 1A 2A 3A 4A 13+
overall p-axis (degrees) p_axis_all_m_1 p_axis 1A 2A 3A 4A 13+
overall duration of p-wave (ms) p_wave_all_m_1 p 1A 2A 3A 4A 13+
overall pq time (ms) pq_time_all_m_1 pq 1A 2A 3A 4A 13+
overall qrs-axis (degrees) qrs_axis_all_m_1 qrs_axis 1A 2A 3A 4A 13+
qt-interval (ms) qt_interval_all_m_1 qt 1A 2A 3A 4A 13+
overall duration of the qrs-complex (ms) qrs_complex_all_m_1 qrs 1A 2A 3A 4A 13+
qt-interval (ms) corrected for heart frequency (hodges) qtc_interval_all_m_1 qtc 1A 2A 3A 4A 13+
overall t-axis (degrees) t_axis_all_m_1 t_axis 1A 2A 3A 4A 13+
negative amplitude of p-wave (microvolt) - lead I - II - III - aVR - aVL - aVF - V1 - V2 - V3 - V4 - V5 - V6 - x - y - z pnegamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 pnegamp_1-6/15-20/23-25 1A 2A 3A 4A 13+
negative amplitude of p-wave (microvolt) - lead v3r pnegamp_v3r_all_m_1 pnegamp_13 1A 3A 13+
negative amplitude of p-wave (microvolt) - lead v7 pnegamp_v7_all_m_1 pnegamp_21 1A 3A 13+
posittive amplitude of p-wave (microvolt) - lead I - II - III - aVR - aVL - aVF - V1 - V2 - V3 - V4 - V5 - V6 - x - y - z pposamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 pposamp_1-6/15-20/23-25 1A 2A 3A 4A 13+
positive amplitude of p-wave (microvolt) - lead v3r pposamp_v3r_all_m_1 pposamp_13 1A 3A 13+
positive amplitude of p-wave (microvolt) - lead v7 pposamp_v7_all_m_1 pposamp_21 1A 3A 13+
amplitude of the q-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z qamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 qamp_1-6/15-20/23-25 1A 2A 3A 4A 13+
amplitude of the q-wave (microvolt) - lead v3r qamp_v3r_all_m_1 qamp_13 1A 3A 13+
amplitude of the q-wave (microvolt) - lead v7 qamp_v7_all_m_1 qamp_21 1A 3A 13+
duration of the q-wave (ms) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z qduration_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 qduration_1-6/15-20/23-25 1A 2A 3A 4A 13+
duration of the q-wave (ms) - lead v3r qduration_v3r_all_m_1 qduration_13 1A 3A 13+
duration of the q-wave (ms) - lead v3r qduration_v7_all_m_1 qduration_21 1A 3A 13+
amplitude of the r'-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z raccamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 raccamp_1-6/15-20/23-25 1A 2A 3A 4A 13+
amplitude of the r'-wave (microvolt) - lead v3r raccamp_v3r_all_m_1 raccamp_13 1A 3A 13+
amplitude of the r'-wave (microvolt) - lead v7 raccamp_v7_all_m_1 raccamp_21 1A 3A 13+
duration of the r'-wave (ms) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z raccduration_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 raccduration_1-6/15-20/23-25 1A 2A 3A 4A 13+
duration of the r'-wave (ms) - lead v3r raccduration_v3r_all_m_1 raccduration_13 1A 3A 13+
duration of the r'-wave (ms) - lead v7 raccduration_v7_all_m_1 raccduration_21 1A 3A 13+
amplitude of the r-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z ramp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 ramp_1-6/15-20/23-25 1A 2A 3A 4A 13+
amplitude of the r-wave (microvolt) - lead v3r ramp_v3r_all_m_1 ramp_13 1A 3A 13+
amplitude of the r-wave (microvolt) - lead v7 ramp_v7_all_m_1 ramp_21 1A 3A 13+
duration of the r-wave (ms) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z rduration_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 rduration_1-6/15-20/23-25 1A 2A 3A 4A 13+
duration of the r-wave (ms) - lead v3r rduration_v3r_all_m_1 rduration_13 1A 3A 13+
duration of the r-wave (ms) - lead v7 rduration_v7_all_m_1 rduration_21 1A 3A 13+
amplitude of the s'-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z saccamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 saccamp_1-6/15-20/23-25 1A 2A 3A 4A 13+
amplitude of the s'-wave (microvolt) - lead v3r saccamp_v3r_all_m_1 saccamp_13 1A 3A 13+
amplitude of the s'-wave (microvolt) - lead v7 saccamp_v7_all_m_1 saccamp_21 1A 3A 13+
duration of the s'-wave (ms) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z saccduration_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 saccduration_1-6/15-20/23-25 1A 2A 3A 4A 13+
duration of the s'-wave (ms) - lead v3r saccduration_v3r_all_m_1 saccduration_13 1A 3A 13+
duration of the s'-wave (ms) - lead v7 saccduration_v7_all_m_1 saccduration_21 1A 3A 13+
amplitude of the s-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z samp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 samp_1-6/15-20/23-25 1A 2A 3A 4A 13+
amplitude of the s-wave (microvolt) - lead v3r samp_v3r_all_m_1 samp_13 1A 3A 13+
amplitude of the s-wave (microvolt) - lead v7 samp_v7_all_m_1 samp_21 1A 3A 13+
duration of the s-wave (ms) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z sduration_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 sduration_1-6/15-20/23-25 1A 2A 3A 4A 13+
duration of the s-wave (ms) - lead v3r sduration_v3r_all_m_1 sduration_13 1A 3A 13+
duration of the s-wave (ms) - lead v7 sduration_v7_all_m_1 sduration_21 1A 3A 13+
deviation from the st segment at 0 ms from the j point (mm) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z st0_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 st0_1-6/15-20/23-25 1A 2A 3A 13+
deviation from the st segment at 20 ms from the j point (mm) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z st20_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 st20_1-6/15-20/23-25 1A 2A 3A 13+
deviation from the st segment at 40 ms from the j point (mm) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z st40_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 st40_1-6/15-20/23-25 1A 2A 3A 13+
deviation from the st segment at 60 ms from the j point (mm) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z st60_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 st60_1-6/15-20/23-25 1A 2A 3A 13+
deviation from the st segment at 80 ms from the j point (mm) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z st80_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 st80_1-6/15-20/23-25 1A 2A 3A 13+
negative amplitude of t-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z tnegamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 tnegamp_1-6/15-20/23-25 1A 2A 3A 13+
positive amplitude of t-wave (microvolt) - lead I - II - III - aVR - aVL - aVF / V1 - V2 - V3 - V4 - V5 - V6 - x - y - z tposamp_i/ii/iii/avr/avl/avf/v1-6/x/y/z_all_m_1 tposamp_1-6/15-20/23-25 1A 2A 3A 13+
ecg.1787153255.txt.gz · Last modified: by simone