User Tools

Site Tools


spirometry_validation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
spirometry_validation [2021/05/06 17:22]
laura [Spirometry validation and reference values]
spirometry_validation [2021/05/06 17:51]
laura
Line 1: Line 1:
 ====== Spirometry validation and reference values ====== ====== Spirometry validation and reference values ======
  
-Researchers from the [[https://​www.rug.nl/​staff/​j.m.vonk/​|University Medical Center Groningen]] performed a validation of the [[Pulmonary Function Test]] from participants at [[1a_visit_1|1A visit 1]] and [[2a_visit_1|2A visit 1]] ([[sections]]:​ [[physical state]] ([[Pulmonary Function Test]]) and [[secondary & linked variables]]).\\+Researchers from the [[https://​www.rug.nl/​staff/​j.m.vonk/​|University Medical Center Groningen]] performed a validation of the [[Pulmonary Function Test]] from participants at [[1a_visit_1|1A visit 1]] and [[2a_visit_1|2A visit 1]]. Additionally,​ reference values have been developed. ​([[sections]]:​ [[physical state]] ([[Pulmonary Function Test]]) and [[secondary & linked variables]]).\\
  
 The spirometry variables can be requested in the Lifelines catalogue or by mail (data@lifelines.nl).\\ The spirometry variables can be requested in the Lifelines catalogue or by mail (data@lifelines.nl).\\
Line 9: Line 9:
   * Test performed according to ATS criteria or   * Test performed according to ATS criteria or
   * Test not performed according to ATS criteria, but clinically reliable.   * Test not performed according to ATS criteria, but clinically reliable.
-In case both the pulmonologist and the Lifelines assistant judged the technical correctness,​ the priority is given to the judgment of the pulmonologist. +In case both the pulmonologist and the Lifelines assistant judged the technical correctness,​ the priority is given to the judgment of the pulmonologist.\\ 
 +**Important:​** part of the spirometry results have been listed as technically invalid, as a result the researchers from the UMCG recommend you to __NOT__ use these results in analyses.\\ 
 +\\
 === Validation rules === === Validation rules ===
 To select only technically valid measurements the following rules were applied: To select only technically valid measurements the following rules were applied:
Line 32: Line 33:
  
  
 +===== Article =====
 +  * Mahon, G. M., Koppelman, G. H., & Vonk, J. M. (2021). Grandmaternal smoking, asthma and lung function in the offspring: the Lifelines cohort study. Thorax, 76(5), 441-447. DOI: 10.1136/​thoraxjnl-2020-215232\\
 +\\
 +\\
 ===== Variables ===== ===== Variables =====
 | **Label English** ​                                           | **Label Dutch** ​                                                    | **Code** ​                      | **Variable** ​            | **Assessment** ​                      | **Age** ​ | | **Label English** ​                                           | **Label Dutch** ​                                                    | **Code** ​                      | **Variable** ​            | **Assessment** ​                      | **Age** ​ |
Line 56: Line 61:
 | FEF75 % predicted ​                                           | FEF75 % voorspeld ​                                                  | fef75_percpredicted_all_c_1 ​   | fef75pp ​                 | [[1A visit 1|1A]] [[2A visit 1|2A]] ​ | 18+      | | FEF75 % predicted ​                                           | FEF75 % voorspeld ​                                                  | fef75_percpredicted_all_c_1 ​   | fef75pp ​                 | [[1A visit 1|1A]] [[2A visit 1|2A]] ​ | 18+      |
 | FEF25_75 % predicted ​                                        | FEF25_75 % voorspeld ​                                               | fef2575_percpredicted_all_c_1 ​ | fef2575pp ​               | [[1A visit 1|1A]] [[2A visit 1|2A]] ​ | 18+      | | FEF25_75 % predicted ​                                        | FEF25_75 % voorspeld ​                                               | fef2575_percpredicted_all_c_1 ​ | fef2575pp ​               | [[1A visit 1|1A]] [[2A visit 1|2A]] ​ | 18+      |
-| change in FEV1 2A versus 1A (liter per year)                 | verandering in FEV1 2A versus 1A (liter per jaar)                   | fev1_change_all_c_1 ​           | dfev1                    | [[1A visit 1|1A]] ​[[2A visit 1|2A]] ​ | 18+      | +| change in FEV1 2A versus 1A (liter per year)                 | verandering in FEV1 2A versus 1A (liter per jaar)                   | fev1_change_all_c_1 ​           | dfev1                    | [[2A visit 1|2A]] ​                   | 18+      | 
-| change in FEV1FVC 2A versus 1A (liter per year)              | verandering in FEV1FVC 2A versus 1A (liter per jaar)                | fev1fvc_change_all_c_1 ​        | dfev1fvc ​                ​| ​[[1A visit 1|1A]] ​[[2A visit 1|2A]] ​ | 18+      | +| change in FEV1FVC 2A versus 1A (liter per year)              | verandering in FEV1FVC 2A versus 1A (liter per jaar)                | fev1fvc_change_all_c_1 ​        | dfev1fvc ​                | [[2A visit 1|2A]] ​                   | 18+      | 
-| change in FVC 2A versus 1A (liter per year)                  | verandering in FVC1 2A versus 1A (liter per jaar)                   | fvc_change_all_c_1 ​            | dfvc                     ​| ​[[1A visit 1|1A]] ​[[2A visit 1|2A]] ​ | 18+      | +| change in FVC 2A versus 1A (liter per year)                  | verandering in FVC1 2A versus 1A (liter per jaar)                   | fvc_change_all_c_1 ​            | dfvc                     | [[2A visit 1|2A]] ​                   | 18+      | 
-| change in FEF75 2A versus 1A (liter per second per year)     | verandering in FEF75 2A versus 1A  (liter per seconde per jaar)     | fef75_change_all_c_1 ​          | dfef75 ​                  ​| ​[[1A visit 1|1A]] ​[[2A visit 1|2A]] ​ | 18+      | +| change in FEF75 2A versus 1A (liter per second per year)     | verandering in FEF75 2A versus 1A  (liter per seconde per jaar)     | fef75_change_all_c_1 ​          | dfef75 ​                  | [[2A visit 1|2A]] ​                   | 18+      | 
-| change in FEF25_75 2A versus 1A (liter per second per year)  | verandering in FEF25_75 2A versus 1A  (liter per seconde per jaar)  | fef2575_change_all_c_1 ​        | dfef2575 ​                ​| ​[[1A visit 1|1A]] ​[[2A visit 1|2A]] ​ | 18+      | +| change in FEF25_75 2A versus 1A (liter per second per year)  | verandering in FEF25_75 2A versus 1A  (liter per seconde per jaar)  | fef2575_change_all_c_1 ​        | dfef2575 ​                | [[2A visit 1|2A]] ​                   | 18+      | 
-| difference in body length adults 2A versus 1A                | verschil in lichaamslengte volwassenen 2A versus 1A                 | spirometry_bodylength_all_c_1 ​ | heightdifference_adults ​ | [[1A visit 1|1A]] ​[[2A visit 1|2A]] ​ | 18+      |+| difference in body length adults 2A versus 1A                | verschil in lichaamslengte volwassenen 2A versus 1A                 | spirometry_bodylength_all_c_1 ​ | heightdifference_adults ​ | [[2A visit 1|2A]] ​                   | 18+      |
spirometry_validation.txt · Last modified: 2022/08/01 15:30 by laura